Technical Specifications
Note
The power supply unit must comply with limits established in IEC/EN
60950 with regards to limited capacity power sources. The maximum
output rating is limited to 100 W.
In the case of power supplies >100 W, a pre-fuse rated at 4 A for 24 V DC
or rated at 8 A for 12 V DC should be provided by the customer.
Electrical data
Description Value
Input voltage range
(ext. power supply)
12 V DC -15% to 24 V DC +15%
Regulated direct current
(low safety voltage)
Max. own input current at
12 V DC
about 150 mA
Max. own input current at
24 V DC
about 100 mA
Input voltage range
( terminals 12/13 )
Low– Active (0V)
Input voltage range
(terminal 10)
+12 V -15 % to +24 V +15 %
Regulated direct current
(low safety voltage)
Safety fuse F1 1 AF, Littelfuse 154001
Contact rating (relay) with ohmic
load
30 V / 1 A
Contact rating (relay) with inductive
load
30 V / 1 A
Safety measure Low safety voltage
Protection system according to
DIN/EN 60529
IP30
Mechanical data
Description Value
Operating temperature range -20°C to +40°C
Storage temperature range -20°C to +60°C