Follow this manual thoroughly to
maintain characteristics of the motor
lock. Do not diverge from this manual
without advice from ASSA.
Warranty fails if product is:
•
Wrong installed.
•
Opened by unauthorised personnel
(broken seal) or if cables/connec-
tors has been cut.
•
Fitted with accessories or parts not
recommended by ASSA.
Maintenance:
•
Approximately twice a year, a small
amount of designated grease should
be applied on latches and bolts.
Highly frequented doors may need
maintenance with shorter intervals.
•
Electric parts need NO maintenance.
•
To maintain desired operation and
security level of installed unit, it is
of great importance to check and
adjust the entire door environment:
–
Lock case and strike plate
–
Lock accessories (Lever handle,
thumb turn etc.)
–
Hinges, framework and door
threshold (sill).
–
Door closer.
NB!!
•
Never use lubricants containing
graphite or solvent, use designated
grease from ASSA only.
•
If any uncertainty regarding instal-
lation, maintenance or warranty
occurs, please contact ASSA or your
local supplier.
•
The safety features of this product
are essential to its compliance with
EN 14846. No modification of any
kind, other than those described in
these instructions, is permitted.
•
The locks 841C and 851C must
always be combined with a door
closer which is proven by test to
keep a door in closed position in
the event of fire.
•
The lock case is intended to sit in
single or double acting wooden,
aluminum or steel door.
Maintenance of motor locks
EN14846 -X8E----- (850C,851C,840C,841C) 0402-CPR-SC0155-14 CE
EN14846 3 X 8 E 0 L 7 1 3 (850C,851C) SC0860-14 Performance
EN14846 3 X 8 E 0 L 5 1 3 (840C,841C) SC0173-15 Performance
EN 50130-4 4P03456-E6 (841C-35,851C-35)
4P03456-E7 (84XC-50,85XC-50)
EMC
EN1634:1 E90 4P01152 Fire
SFF3522-1093 Class 4/Class 5
8