Installation Instructions
Product Components
A 7000 Series Electric Strike Body
B 12-Volt and 24-Volt Plug In Connectors
C Pigtail Connectors
Specifications
Electrical Ratings
for Solenoid Continuous Duty Intermittent Duty*
Voltage 12 VDC 24 VDC 12–16 VAC 24 VAC
Resistance in Ohms 50 200 50 200
Amps .24 .12 .24.32 .12
Solenoids are rated at +/– 10% indicated value.
* 10% max duty cycle (2 min. max on time)
For inductive kickback protection, consider using with the HES 2005M3
SMART Pac
®
III or 2001M Plug-in Bridge Rectifier with built-in MOV.
Minimum Wire Guage Requirements
Voltage 12 VDC 24 VDC
200 feet or less 18 guage 20 guage
200–300 feet 16 guage 18 guage
300–400 feet 14 guage 16 guage
Lengths based on round trip.
7000 Series Rating: For Indoor Use Only
Model 791 / 792 783S / 786S / 789S
Static Strength 1,500 lbs 1,000 lbs
Dynamic Impact 70 ftlbs 50 ft–lbs
Endurance 500,000 cycles 500,000 cycles
UL294 Performance Levels*
Destructive Attack Level I (No attack test)
Line Security Level I (No line security)
Endurance Level IV (100,000 cycles)
Standby Power Level I (No secondary power source)
* Monitor options were not evaluated by UL294/UL1034/ULC60839-11-1
7000 Series
Electric Strike
or
A
B
C