High pressure transducer fault
(Optional)
A33 2# The sensor is open or short circuit
Check or change the sensor
Exhaust temperature switch 1
failure
A42
Gas temperature (outlet) too high.
Possible system blockage
Check sensor and gas circuit
Exhaust temperature switch 2
failure
A43
Gas temperature (outlet) too high.
Possible system blockage
Check sensor and gas circuit
Temp. differential between
water-in and water-out is too
large
A44
Water flow volume not enough. Water
pressure is too low
Check the water flow volume or
water pipes blocked
External air temperature too
low
A46
The external air temperature is lower
than the limit fixed
Check sensor and external air
temperature
Check or change the fan motor
protection
A51
AC contactor adhesions Check the AC contactor
Check electrical connections
wrong
A91
Wrong connections or lack of connection
Check connections of power input
wire
Some phase has no voltage
Check electrical connections
protection
A93 Compressor overcurrent Check the system
protection
A94
Compressor overcurrent Check the system
The time limit running failure
Signal failure
- -
The cable between the display and the
card is badly connected
Check the continuity of the cable, and
the terminal and the cables are well
connected