Questions and Answers

  • P
    parrishstephenAug 25, 2025
    What to do if my Astralpool PROELYXP11i Heat Pump shows a water flow failure TS1?
    • L
      Leslie OlsenAug 25, 2025
      If your Astralpool Heat Pump displays a water flow failure TS1, it could be due to a damaged water flow switch or insufficient water flow. Try replacing the water flow switch or checking the filtration pump and waterway system to ensure adequate water flow.
  • M
    Mary JacobsAug 25, 2025
    Why is my Astralpool PROELYXP11i showing compressor current protection?
    • E
      Elizabeth MurphyAug 26, 2025
      Compressor current protection in your Astralpool Heat Pump can occur due to several reasons: the compressor current being too large instantaneously, incorrect connection for compressor phase sequence, compressor accumulations of liquid and oil, a damaged compressor or driver board, abnormal water flow, or power fluctuations. To resolve this, check the compressor, compressor phase, power range, phase sequence connection, the waterway system and filtration pump, and mains power input.
  • T
    Tom JonesAug 26, 2025
    What causes T6 exhaust too high protection in Astralpool Heat Pump?
    • K
      kellyericAug 27, 2025
      T6 exhaust too high protection in your Astralpool Heat Pump can result from a lack of gas, low water flow, a blocked piping system, or a faulty exhaust temperature sensor. Address this by checking the high-pressure gauge and filling with gas if needed, inspecting the waterway system and filtration pump, checking the piping system for blockages, and replacing the exhaust temperature sensor.
  • W
    wolfedouglasAug 27, 2025
    What to do if my Astralpool Heat Pump displays a low pressure failure TS5?
    • R
      Robert BooneAug 27, 2025
      If your Astralpool Heat Pump is showing a low pressure failure TS5, it could be caused by a blocked EEV or jammed pipe system, abnormal motor speed or motor damage, or gas leakage. You should check the EEV and piping system, check the motor, use a high-pressure gauge to check the pressure value and check the refrigeration system.
  • B
    brittneyvasquezAug 27, 2025
    How to fix communication failure between controller and main board in Astralpool PROELYXP11i?
    • T
      tmontoyaAug 27, 2025
      A communication failure between the controller and main board of your Astralpool Heat Pump is often due to a poor signal wire connection, a damaged signal wire, or a controller malfunction. Check and reconnect the signal wire, replace the signal wire, turn off the electricity supply and restart the machine, or replace the controller.
  • A
    Andrea KrauseAug 28, 2025
    What causes over heating protection for water temperature (T2) in heating mode in Astralpool Heat Pump?
    • N
      nclarkAug 28, 2025
      Overheating protection for water temperature (T2) in heating mode in your Astralpool Heat Pump can be triggered by low water flow, a stuck water flow switch cutting off water supply, or a faulty T2 sensor. Check the waterway system, the filtration pump or water flow switch, and the T2 sensor, replacing components as necessary.
  • J
    jamesmunozAug 29, 2025
    How to troubleshoot controller failure in Astralpool PROELYXP11i?
    • P
      pblairAug 29, 2025
      Controller failure in your Astralpool Heat Pump can stem from poor wire connections, damaged signal wires, or the controller itself failing. Try checking and reconnecting the signal wire, replacing the signal wire, turning off the electricity supply and restarting the machine, or replacing the controller.
  • E
    Erin StevensAug 30, 2025
    What does 'T2 water temp. Too low protection under cooling mode' mean for my Astralpool Heat Pump?
    • A
      Ashley RussellAug 30, 2025
      The 'T2 water temp. Too low protection under cooling mode' error in your Astralpool Heat Pump indicates either low water flow or a problem with the T2 temperature sensor. Check the filtration pump and waterway system or replace the T2 temperature sensor.
  • K
    kbeckerAug 23, 2025
    What causes high pressure failure TS4 in Astralpool Heat Pump?
    • R
      rhodesshaneAug 25, 2025
      High pressure failure TS4 in your Astralpool Heat Pump can be caused by several factors: the ambient temperature being too high, the water temperature being too high, low water flow, or an issue with the fan motor (abnormal speed or damage). To address this, check the water flow and filtration pump, inspect the fan motor, and examine and repair the piping system.
  • L
    Lindsey BallAug 31, 2025
    What to do if my Astralpool PROELYXP11i shows VDC voltage too high protection?
    • D
      David GatesAug 31, 2025
      If your Astralpool Heat Pump shows a VDC voltage too high protection error, it indicates that the line voltage is too high or the driver board is damaged. Check if the power is in the normal range and change the driver board or main board.

Summary

Description

Specifications

Technical data PRO ELYO INVERBOOST NN pool heat pumps

Overview of technical specifications.

General data

General technical parameters of the heat pump.

Location and connection

5.1 Heat pump location

Guidelines for placing the unit outdoors.

5.4 Initial operation

Steps for the first start-up of the unit.

Electrical Wiring

6.1 Inverter swimming pool heat pump wiring diagram

Wiring diagram for models 71676-71680.

6.3 Inverter swimming pool heat pump wiring diagram

Wiring diagram for models 71682/71683.

6.5 Inverter swimming pool heat pump wiring diagram

Wiring diagram for models 68821/68823.

6.6 Electrical connection

Guidelines for electrical installation and safety.

Start-up of the Heat Pump

7.2 The keys and their operations

Explanation of buttons and their functions.

7.3 Heating operation logic

Logic table for heating operation.

7.4 Cooling operation logic

Logic table for cooling operation.

Troubleshooting

8.1 Error code display on LED wire controller

Lists error codes and their solutions.

Protection Remarks and Examples

Explains specific protection functions.