SUBJECT:
MODEL:
5200
Printed Circuit Board
(CAO
18087)
DATE:
june
6,
1983
I
PROBLEM
AND
SOLUn0E)r
Some 5200
units
display
a
blank
dark
screen
or
a
screen
with
garbled
information.
The
probable
cause
for
either
of
these
symptoms
is
an
intermittent
solder
short
(bridge) on
the
PCB
betwm
the'
A0
Address
line
.trace
and
the
fetdthru
pad
of
the
REF
Line
trace
(near
connector
J
1).
TROUBLESHOOTING:
8
The
problem
has
ken
seen
to
occur
during
one of
the
following
three
instances
1)
When
the
system
is
powered-up
-
the
screen
is
usudly
blank
and
dark.
2)
After
the system
is
powered-up
with
a
cartridge
in
place
-
the
screen
will
display
random
garbled
data.
3)
Either
of
the
above
can
be
seen
when
th;
PCB
is
moved
or
siightiy
flexed
near
connector Jlw
SOLUilON:
To
remedy
the
problem, perform the following
five
procedures
in
the
exact
order
given:
Turn
off
power,
and
disconnect
AC
and
interconnect
cables.
Disassemble
unit
to
expose
the component side of
the
(CA018087).
Locate
connector
31,
the
adjacmt
A0
Address
trace
and
the
fnd-thru
pad
of
the
REF Tace
(See
Figure
I).
Carefuliy
remove
the
excess
solder
from
the
pad
and
wipe
the
area
dean.
Inspect
the
pad
and
if
necessary
use
an
X-o
knife
to
cut
a
shallow
groove
between
the
A0
Address
Line
and
the
feedthru
pad. Be
very
carefuly
not
nick
or
cut
the
trace
adjacmt
m
the
pad.
Reassemble
and
test the
unit