Change the chime
To change the chime, go to:
Update ->Message -> Chime setting.
Here you can change or disable the post-chime and the pre-chime.
Set up the time
In the PPM-IT5, the time can be set up by the user or automatically by NTP (Network
Time Protocol). Go to:
Setup1 -> Basic Setting -> System Time
If you choose: enable for the NTP, you will need to give the IP address of the NTP server.
Start an event with the scheduler
1- Create in the function libraries page, the function you want to start with the
scheduler.
2- Verify that the time is properly set up ->Setup 2/ System Time.
3- Open the scheduler page: Setup2/Scheduler and link a function to an event.
Control an ECS with the PPM-IT5
You can dial for the ECS with the PPM-IT5. Please check the ECS manual to know the
settings in the Ateis Studio Software. The only thing you have to set up in the PPM-IT5 itself
is:
Setup 1 -> basic settings -> dial agent -> agent service -> enable.
The IP address will be the IP address of your ECS.
Use the PPM-IT5 with UAPG2
On the UAP side:
Make sure that the UAPG2 and the PPM-IT5 are in the same IP range(Factory setting of the
UAPG2 is 192.168.100.6 and PPM-IT5 is 192.168.100.1).
Click the PPM Touch block and select a channel on which the PPM-IT5 should work.
Click the level controller, set the level controller to pervert output level (in this case +10dB)
Compile and store.
This is all the needs to be done in the UAPG2 to make the connection.
Selection of the Zones will be done in the PPM-IT5.