EasyManua.ls Logo

Atlantic Compact 150 L - GIFAM Recommmendations; Mechanical Risks; Electrical Risks; Hydraulic Risks

Atlantic Compact 150 L
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
InstallationManual
3535
GB
RecommendationsbyGIFAM
Recommendations approved by GIFAM (the Interprofessional Group of Domestic Appliance Manufacturers) on
the correct installation and use of the product.
1.Mechanicalrisks
Handling
Theappliancemustbehandledandinstalledinawaysuitedtotheweightandsizeoftheappliance.
Location
Theapplianceshouldbeshelteredfromtheweatherandprotectedfromfrost.
Positioning
Theapplianceshouldbepositionedasrecommendedbythemanufacturer.
2.Electricalrisks
Connections
• Connecttheapplianceaccordingtothemanufacturersdiagramsandinstructions.Takeparticularcarenotto
neutralisethethermostat;directconnectionisforbidden.
• Toavoidthesupplycableoverheating,usethetypeandsectionofcablerecommendedintheinstallation
manual.Inanyevent,complywiththeregulationsinforce.
• Makesurethatthereisanelectricalprotectionbetweenthemainsandtheapplianceanduser(forexample
inFrance,a30mAdifferentialcircuit-breaker).
• Checktheconnectionsaretight.
• Theappliancemustbeconnectedtoagoodearthconnection.
• Ensurethatlivepartsremaininaccessible.Coversmustbepresentintheiroriginalconditionandopenings
forcablesofasuitablediameter.
• Beforeremovingthecover,makesurethepoweristurnedoff.
3.Hydraulicrisks
Pressure
Theappliancesmustbeusedwithintherangeofpressuresforwhichtheyweredesigned.
Connection, drains
• Theinstallationofahydraulicsafetyunit,includingatleastapressurevalve,iscompulsory.Itmustbemoun-
teddirectlyonthecoldwaterinlet.
• Donotblockthedrainopeningofthevalve.Connectthedrainopeningofthevalvetoawastewateroutlet.
• Ifthereisexcessivepressure,theowmustnotbesloweddowninanyway.
Connectthesafetyunittoadrainpipe,keptintheopenair,inafrost-freeareaandonacontinuousdownward
slopetodrainanyexpandedheatedwaterortodrainthewaterheater.
Thismeansthatthedrainpipe’sdiametermustbeadaptedtotheow.
• Takecarenottoreversethehotwaterandcoldwaterconnections.
• Checkforleaks.