MaintenanceManual
3939
GB
2.2 Installation not matching the regulations, standards and good prac-
tice, including:
• New safety valve missing or not installed according to standard EN 1487 or modication to the setting,
hydraulicsystemdirectlyinstalledonthewaterheaterthatpreventsthesafetyunitfromworking(pressure
reducingvalve,stopvalve,etc.)
• Nocouplings(castiron,steelorinsulating)onthehotwaterconnectionpipes,whichcouldcausecorrosion.
• Faulty electrical connections: not to standard NFC 15100, incorrectly earthed, insufciently thick cable,
connectionusingexiblecables,failuretocomplywiththemanufacturer’swiringdiagrams.
• Appliancenotpositionedasshownintheinstructions.
• Abnormaltappingcorrosion(hotorcoldwater)duetoafaultyconnection(badseal)orfaultydielectriccou-
pling(directiron/coppercontact).
• Electricalprotectivecovermissingorbadlyinstalled.
• Cableentrymissingorbadlyinstalled.
• Fallofanapplianceduetoinappropriateattachmentpoints.
2.3 Defective maintenance
• Abnormalscaledepositsontheelementsorsafetydevices.
• Nomaintenanceofthesafetysystemleadingtoexcesspressure.
• Modicationoftheoriginalequipmentwithoutthemaker’sapprovaloruseofsparesnotapprovedbyhim.
3.After-salesdepartment
Thepartsofthewaterheaterthatcanbereplacedareasfollows:
• Doorseal
• Electronicthermostatassembly
• Heatingelement
• Magnesiumanode
For water heaters Steatite Magnesium :
• Sheath for ceramic element
OnlyusesparepartsreferencedbyAtlantic.
Toorder,pleasespecifytheexactcodeandserialnumberofthewaterheater(inset)indicatedontheap-
pliance’sidenticationplateplacedneartheelectricalequipment.
Allworkontheproductshouldbeperformedbyaspecialist.