Oil filler plug
Testing
The valve can be tested on a separate compressed air line.
Before removing the safety valve, stop the compressor (see section Stopping), close the air outlet
valve, switch off the voltage, open the isolating (disconnector) switch (IG), open drain valves (4)
(tank-mounted units) and the manual drain valve (5) (if fitted - on floor-mounted units) and
unscrew filler plug (3) one turn to permit any pressure in the system to escape.
If the valve does not open at the set pressure stamped on the valve, replace the valve.
No adjustments are allowed. Never run the compressor without a safety valve.
7.4 Belt set exchange and tensioning
Read the warning in the Preventive maintenance schedule section.
Instruction book
68 2920 7119 21

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco G 15L and is the answer not in the manual?

Atlas Copco G 15L Specifications

General IconGeneral
ModelG 15L
TypePiston
Working Pressure8 bar
Noise Level72 dB(A)
Free Air Delivery (FAD)150 l/min
Max Pressure8 bar