108
Instruction book
9096 3321 00
- Consult the sections Electric cable size, Installation proposal and Dimension drawings
-
The following transport fixtures, painted red, must be removed:
Bolts (1)
Bushes (2)
Supports (3)
- Check that the electrical connections correspond to the applicable codes and that all wires are
clamped tight to their terminals.
The installation must be earthed and protected against short circuits by fuses of the inert type
in all phases. An isolating switch must be installed near the compressor.
-
Check transformer (T1) for correct connection.
Check the settings of drive motor overload relay (F21).
Check that the motor overload relay is set for manual
-
On air-cooled compressors, check the setting of circuit breaker (Q15). Also check that the
switch on the circuit breaker is in position I.
Fit air outlet valve (AV); see section Introduction for the location of the valve.
Close the valve.
Connect the air net to the valve.
On compressors equipped with a dryer bypass, fit the air outlet valve to the dryer bypass
- Connect the condensate drain outlet(s) to a drain
collector. See section Condensate system.
-
For compressors with a DD or a DD and PD filter connect the automatic drain of the filters to a
suitable drain collector.
- On water-cooled compressors, drain valves, shut-off valves and a regulating valve should be
fitted by the customer in the cooling water piping.
Electric cubicle ,GA 37
+
up to GA 75
F16/17/18
F1/2/3 K25
T1
PE
PE
F21
F15
X103
X108AX108
X117
K21
K22
K23
1X0