Instruction book
9096 3321 00
(A): Air inlet temperature
(B): Condensation temperature
(C): Working pressure
(D): Relative air humidity
Example: If operating at a pressure of 10 bar(e) in an ambient temperature of 20 °C and at a relative air
humidity of 100%, the minimum temperature to prevent condensate from forming is 68 °C . Regulate the cooling
water flow during loaded operation to obtain a temperature between 70 and approx. 75 °C at the outlet of the
compressor element.
7.5 During operation
Warnings
The operator must apply all relevant Safety precautions. Also consult section Problem
solving.
Keep the doors closed during operation; they may be opened for short periods only to carry
out checks.
When the motors are stopped and LED (8) (automatic operation) is alight, the motors may
start automatically.
Checking the oil level
When the automatic operation LED (8) is lit, the regulator is automatically controlling
the compressor, i.e. loading, unloading, stopping of the motors and restarting!
Control panel Elektronikon Graphic