- Condition Fault Remedy
Condensate is not discharged
from condensate separator
during loading
Discharge flexible clogged Check and correct as
necessary
-
Condition Fault Remedy
Compressor air output or
pressure below normal
Air consumption exceeds air
delivery of compressor
Check equipment connected
Choked air filter element Replace filter element
Solenoid valve malfunctioning Replace valve
Leak in control air flexibles Replace leaking flexibles
Inlet valve does not fully open Have valve checked
Oil separator clogged Have element replaced
Air leakage Have leaks repaired
Safety valve leaking Have valve replaced
Compressor element out of
order
Consult Atlas Copco
-
Condition Fault Remedy
Excessive oil flow through air
inlet filter after stopping
Check valve leaking or oil
stop valve jammed
Replace defective parts.
Replace air filter element
-
Condition Fault Remedy
Safety valve blows after
loading
Inlet valve malfunctioning Have valve checked
Minimum pressure valve
malfunctioning
Have valve checked
Safety valve out of order Have valve replaced
Compressor element out of
order
Consult Atlas Copco
Oil separator element clogged Have element replaced

Table of Contents