Instruction book
9096 3321 00
Note: The cooling fan is not provided on water-cooled compressors.
Description
Air drawn through filter (AF) and open inlet valve (IV) into compressor element (E) is compressed. A mix
of compressed air and oil flows into the air receiver/oil separator (AR) via check valve (CV). The air is
discharged through outlet valve (AV) via minimum pressure valve (Vp) and air cooler (Ca).
The air cooler is provided with a moisture trap (MT).
On Full-Feature compressors, the air flows through air dryer (DR) before it is discharged through outlet
valve(AV). Also see section Air dryer.
Reference Description
A Intake air
B Air/oil mixture
C Oil
D Wet compressed air
F Condensate
G Dry compressed air
Flow diagram, GA Workplace Full-Feature