3. Clean the filter seats on the manifold. Oil the gaskets of
the new filters and screw them into place until the gaskets
contact their seats, then tighten by hand.
4. Tighten filler plug (FC1).
5. Reset the oil filter service warning using key <<Reset>>
in submenu <<Service>>. 1)
4.6 Storage after installation
Run the compressor, e.g. twice a week, until warm. Load and
unload the compressor a few times to operate the components
of the unloading/loading system.
If the compressor is going to be stored without running from
time to time, protective measures must be taken. Consult Atlas
Copco.
1) See "User manual for Elektronikon regulator", section "Submenu
SERVICE".
CV. Check valve
DP2. Oil drain plug, oil stop valve
DP3. Oil drain plug, check valve
DP5. Oil drain plug, gear box
E. Compressor element
Vs. Oil stop valve
Fig. 13. Compressor element
AF. Air filter
AV. Air outlet valve
Ca. Air cooler
Co. Oil cooler
DP4. Oil drain plug
DP6. Water drain plugs
FN2/3. Fans
M1. Drive motor
M2/3. Fan motors
MTa. Moisture trap
1. Bolt
2. Air outlet pipe
Figs. 14. Drive motor and coolers (typical examples)
Fig. 14a GA
Fig. 14b GA W
DP3
CV
DP2
Vs
E
DP5
50318F
FN3
Ca
M2
FN2 Co
1
1
2
AV
M1
AF
M3
MTa
50317F
Co
Ca
DP4
DP6
DP6
M1
50321F