136
Instruction book
9096 3313 00
11.7  Compressor data
Reference conditions
GA55
+
On water-cooled units also:     
Maximum cooling water outlet 
temperature 
°C  50 
Maximum cooling water inlet 
pressure 
bar(e)  5 
 
   
All data specified below apply under reference conditions, see section Reference 
conditions and limitations. 
 
 
 
Units
 
7.5 bar
 
8 bar
 
10 bar
 
Frequency
  Hz  50  50  5 
Maximum (unloading) 
pressure, units 
without dryer
 
5bar(e)
  7.5  8  1 
Maximum 
(unloading) 
pressure, Full-
Feature units
 
bar(e)
 
75.2
 
75.7
  9.7 
Reference working 
pressure, units 
without dryer
 
bar(e)
  7  8  9. 
Reference working 
pressure, Full 
Feature units
 
bar(e)
  7 
75.7
  9. 
Pressure drop over 
dryer, Full-Feature units
 
bar(e)
 
3.2
 
3.2
  0.2 
Set point, 
thermostatic valve
 
°C  40  40  4 
Temperature of air 
leaving outlet valve 
(approx.), units without 
dryer
 
°C  30  30  3