Power Focus 6000 LV EN Installation
© Atlas Copco Industrial Technique AB - 9839 1081 01
11
Pin Use
1 Do not use
2 Do not use
3 Attach an emergency button be-
tween pin 3 and pin 4
4 See pin 3
5 Attach an emergency button be-
tween pin 5 and pin 6
6 See pin 5
7 Connect jumper between pin 7 and
pin 8
8 See pin 7
9 Connect jumper between pin 9 and
pin 10
10 See pin 9
Single controller without EM Stop button
WARNING Remote start switch must be set to OFF for this configuration
Connector: Phoenix, 6-pin Headers 3.5mm pitch
Use the following pin configuration:
Pin Use
1 Do not use
2 Do not use
3 Connect a jumper between pin 3
and pin 4
4 See pin 3
5 Connect a jumper between pin 5
and pin 6
6 See pin 5
7 Connect a jumper between pin 7
and pin 8
8 See pin 7
9 Connect a jumper between pin 9
and pin 10
10 See pin 9
Multiple controllers with EM Stop button
The PIN configuration differs depending on the location of the controller in the EM stop chain.
First controller with an EM Stop button connected
EM Stop button connector: Phoenix, 6-pin Headers 3.5mm pitch