Installation EN Power Focus 6000 LV
14
© Atlas Copco Industrial Technique AB - 9839 1081 01
AWG 22 cable Maximum total length
8 controllers 70 meters
10 controller 50 meters
PIN configurations for emergency stop
The Power Focus has an external EM Stop interface and I/O-bus on the connector board that is located
behind the front access door.
The PIN configuration differs depending on if it is a single or multiple controller solution. Furthermore, for
the single controller the PIN configuration differs depending on if the controller is equipped with an EM
Stop button.
Single controller with EM Stop button
Connector: Phoenix, 6-pin Headers 3.5mm pitch
Use the following pin configuration:
Pin Use
1 Do not use
2 Do not use
3 Attach an emergency button be-
tween pin 3 and pin 4
4 See pin 3
5 Attach an emergency button be-
tween pin 5 and pin 6
6 See pin 5
7 Connect jumper between pin 7 and
pin 8
8 See pin 7
9 Connect jumper between pin 9 and
pin 10
10 See pin 9
Single controller without EM Stop button
WARNING Remote start switch must be set to OFF for this configuration
Connector: Phoenix, 6-pin Headers 3.5mm pitch
Use the following pin configuration: