- 126 -
rating type acc. ISO 3046-7 ICXN ICXN
Coolant coolant coolant
Combustion system direct injection direct injection
Aspiration turbo charged turbo charged
intercooled intercooled
Number of cylinders 6 6
Swept volume 7.15 l 7.15 l
Speed governing electronic electronic
Governer type EMS 2 EMS 2
Capacity of oil sump - initial fill 29 l 29 l
Capacity of cooling system 34 l 34 l
Electrical system 24 Vdc 24 Vdc
Emission compliance EU STAGE III EU STAGE III
Maximum permissible load factor of PRP during 24h period 4) 70% 70%
Design data alternator Standard IEC34-1 IEC34-1
ISO 8528-3 ISO 8528-3
Make Leroy Somer Leroy Somer
Model LSA 46.2 M5 LSA 46.2 M5
Rated output, class H temperature rise 200 kVA 250 kVA
rating type acc. ISO 8528-3 “BR” 125/40°C “BR” 125/40°C
Degree of protection (IP index acc. NF EN 60-529) IP 23 IP 23
Insulation stator class H H
Insulation rotor class H H
Number of wires 12 12
Power circuit Circuit-breaker, 3ph.
Number of poles 4 4
Thermal release It (higher at 25°C) 400 A 400 A
Magnetic release Im 3..5xIn 3..5xIn
Fault current protection
Residual current release IDn 0.030-30 A 0.030-30 A
Insulation resistance (optional) 10-100 kOhm 10-100 kOhm