- 21 -
2.4 Electrical features
The electrical features described in this chapter are
standard provided on this generator. For all other
electrical features, see “Overview of the electrical
options” on page 119.
2.4.1 Control and indicator panels
To operate the generator, the QAS 200-250 control
panel contains a Qc1002™, Qc2002™, Qc1103™,
Qc2103™ or Qc4002™ MkII controller. This
controller is located inside the control cubicle, and
communicates via a display located at the front. The
controller will carry out all necessary tasks to control
and protect the generator, which allows operation in
many different applications.
2.4.1.1 Control panel with Qc1002™
controller
General description Qc1002™ control panel
A1 .......Qc1002™ display
F10......Fuse
The fuse trips when the current from the
battery to the engine control circuit exceeds
its setting. The fuse can be reset by pushing
the button.
H0 .......Panel light
S2 .......Emergency stop button
Push the button to stop the generator in case
of an emergency. When the button is
pressed, it must be unlocked, before the
generator can be restarted. The emergency
stop button can be secured in the locked
position with the key, to avoid unauthorized
use.
S20......ON/OFF switch
Position O: No voltage is supplied to the
Qc1002™ module, the generator will not
start.
Position I: Voltage is supplied to the
Qc1002™ module, it is possible to start up
the generator.
X25 .....Terminal strip
Qc1002™ Module
Q2
N13
Q1
H0
S2
A1
S20
F10
L1L2
OFF
L1-N
L2L3 L2-N
L3L1
LL LN
L3-N
X25
Qc1002 CAN
v x.xx.xx