EasyManua.ls Logo

Atlas Copco XAHS 146 Dd S3B APP

Atlas Copco XAHS 146 Dd S3B APP
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 49 -
FAULT CODES
There are several parameters that are continuously
watched.
When one of these parameters exceeds its specified
limit the compressor will react depending the present
status of the control box.
The message displayed can be a warning, a shut down
or a start failure.
Display text Warning Shutdown Wait to start
Engine Fault Codes (Canbus SAE J1939):
Engine Sensor Failure X X
Fuel Temperature High X X
Fuel Pressure Low X X
Coolant Temperature High X X
Injector Failure X X
Oil Pressure low X X
Air Inlet Temperature High X X
Turbo Boost Pressure High X X
Oil Temperature High X X
Water in Fuel X X
Xc2002 Fault Codes:
Sensor Failure (Fuel Level, Vessel Pressure, Regulating
Pressure, Element Temperature)
X
Can SAE J1939 Communication Failure X
Overspeed X
Fuel Level Low X X
Vessel pressure High X
Element Temperature High X X
Coolant Level Low X
Vessel Pressure Start Prevention X
Battery Voltage Low X
Battery Charge Failure X
Check Airfilters X
Start Failure X
Stop Failure X
Service Timer 1 X
Service Timer 2 X
Emergency Stop X

Table of Contents

Related product manuals