- 34 -
STARTING
Switch on the battery switch if so equipped.
Switch the controller on by pressing the power button.
The instrument panel will now perform a selftest; the
following display will be shown and the controller is
initialized:
During initializing all buttons/inputs/outputs/alarms are
inactive.
This view will be shown for about 2 seconds, after which
the display will show the Main View.
The actual vessel pressure is shown. If the measured
vessel pressure is higher than 1.5 bar, the unit will not
start. The vessel pressure has to be lowered by opening the
blow down valve. After power up, the vessel pressure
normally is low enough to proceed with the starting
procedure.
The display now shows
The machine is now ready to be started and is waiting for
a start command.
The display now shows
Press the START button to power-up the engine
electronics (ECU).
As soon as communication between compressor controller
and engine controller is established, the machine will
preheat according to the parameters of the engine
controller.
Xc2003
v1.00.0 (r7307)
Active Buttons
Measurement View Button
Settings View Button
Alarms View Button
Active Buttons
Start Button
(to initiate Start command)
Measurement View Button
Settings View Button
Alarms View Button