- 36 -
The engine starts running at idle speed. The display shows
The engine will run at minimum rpm, until the engine’s
coolant temperature reaches 40 deg C (104 deg F), with a
minimum time of 15 seconds and a maximum time of 300
seconds.
The display now shows After warming up the machine is ready to be loaded and is
waiting for a load command; the display shows
MAIN VIEW
ENGINE WARMING UP
1200RPM 3.3 bar1286h
40°C
25°C
13°C
300s
76s
0s
40%
Active Buttons
Stop Button
(to cancel Start command)
Measurement View Button
Settings View Button
Alarms View Button
MAIN VIEW
ENGINE WARMING UP
1200RPM 2.9 bar1286h
30s
7s
0s
40%
Active Buttons
Stop Button
(to cancel Start command)
Load Button
(to initiate Automatic Load)
Measurement View Button
Settings View Button
Alarms View Button