When the compressor is shut down because of
exceeding a parameter setting (e.g. compressor
temperature) the display shows:
and then:
After the stopping procedure has ended press F1 to
continue.
Restarting before the parameter is within its limits is
impossible because of the parameter check before the
cranking procedure.
STOPPING
To turn off the compressor first press the button “0”.
The engine will run some time at min. speed to cool
down and will stop finally.
The remaining time is shown in the display:
Meanwhile the air receiver is depressurised.
Switch the “ON/OFF” switch to the position “OFF”.
Wait until the display is dark.
Switch the battery switch in the “OFF” position.
STARTING/STOPPING VIA REMOTE CONTROL
(O)
(ON/OFF)
Always use the remote control function
in accordance to local/work area
legislation.
1 Start Engine
2 Stop Engine
3 Load/unload compressor