- 86 -
AFTER-COOLER
An integral after-cooler, with water separator (1), is
available to reduce the outlet air temperature to
ambient plus 10°C (18°F) and cut water content to a
mere 15%. The installation includes a by-pass over
the after-cooler.
For applications that demand quality air, a fine
filtration unit (2) can be specified with the after-
cooler package. This will remove oil and particles
down to 0.01 mg/m
3
.
For purer, but not breathing, air, an active charcoal
filtration unit (3) can be specified with the after-
cooler package. This removes oil and oil vapour
content to 0.003 mg/m
3
.
REMOTE START
The remote start allows the user to start, stop the
compressor and switch to load/noload by radiosignal.
This is particularly comfortable when the compressor
can not be positioned directly at the job site because
of blocking by buildings or other obstacles.
INTERNAL LIGHTNING
The internal lighting circuit is equipped with a timer.
When the internal lighting is switched on, the timer is
started. After a preset time the internal light will be
switched off automatically.
(1)
(2)
(3)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco XRXS 567 Cd and is the answer not in the manual?

Atlas Copco XRXS 567 Cd Specifications

General IconGeneral
BrandAtlas Copco
ModelXRXS 567 Cd
CategoryAir Compressor
LanguageEnglish

Related product manuals