4 Installation
4.1 Installation warnings
Working with machinery controlled by a frequency converter requires special
safety precautions which depend on the type of network (TN, TT or IT). Consult
Atlas Copco.
Thermal insulation should be provided to offer protection against the high
temperature of the air outlet valve and air delivery pipe.
Consult the “Safety precautions during installation” before starting the installation.
Cooling air for starter cabinet:
Contamination levels (ambient) according to IEC 60 721-3-3.
Chemical gases: Class 3C2
Solid particles: Class 3S2
No conductive dust allowed
No condensation allowed
Maximum allowed relative humidity is 60 % in the presence of corrosive
gases.
When good EMC practices for installation are followed, the compressor qualifies
for installation in EMC category C3, according to EN61800-3, for use in a 2nd
environment (a 2nd environment includes all establishments other than those
directly connected to a low voltage power supply network which supplies buildings
used for domestic purposes).
The compressor is not intended to be used on a low-voltage public network which
supplies domestic premises. Radio frequency interference can be expected if used on
such a network.
Instruction book