5.5 Stopping
Elektronikon regulator
1. Press the test button on top of all electronic drains to discharge the condensate. See Air
dryer on Full-Feature.
2. Press the stop button (6) of the Elektronikon regulator: the compressor will stop and the sign
for automatic operation (4) will go out.
3. Close the air outlet valve (customer's installation).
4. Open the manual condensate drains.
In case of emergency, press the emergency stop button to stop the compressor
immediately.
Use the emergency stop button only in case of emergency!
5.6 Taking out of operation
Procedure
At the end of the service life of the compressor, proceed as follows:
1. Stop the compressor and close the air outlet valve.
2. Switch off the voltage and disconnect the compressor from the mains.
3. Shut off and depressurize the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
4. Drain the water and condensate circuits.