EasyManua.ls Logo

ATON AH66T - Page 58

ATON AH66T
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ATON AH66T INSTALLATION MANUAL
© ATON 2010 | All rights reserved. Page 57
Doorbell Control
Description: Activates, Deactivates or TOGGLES Page/Doorbell Audio Input. Status can be
queried.
Examples:
&AH66,DB,0<cr> Sets DOORBELL INPUT (DB) to OFF (0).
&AH66,DB,1<cr> Sets DOORBELL INPUT (DB) to ON (1).
&AH66,DB,2<cr> TOGGLES (2) DOORBELL INPUT (DB).
&AH66,DB,?<cr> QUERIES (?)DOORBELL INPUT (DB) status
Possible QUERY responses are:*AH66,DB,0 or *AH66,DB,1, where 0=OFF and 1=ON.
Doorbell and Page commands are separated because the volume for DOORBELL audio
and PAGE audio is independently set in the ATON configuration software.
Factory Default
Description: Sets all options back to the FACTORY DEFAULT settings.
Command:
&AH66,DEF<cr> Factory DEFAULTS (DEF) the chassis.
Prefix Command Parameter 1
Doorbell State
&AH66 DB 0/1/2/?
Prefix Command
&AH66 DEF

Table of Contents