10.1. Switch compartment: open/close
Figure 62: Open/close switch compartment
[A] Mechanical position indication (self-adjusting)
[B] Mechanical position indication via indicator mark
Flameproof enclosure, danger of explosion!
Risk of death or serious injury.
Before opening, ensure that there is no explosive gas and no voltage.
Handle cover and housing parts with care.
Joint surfaces must not be damaged or soiled in any way.
Do not jam cover during fitting.
Open
1. Loosen screws [2] and remove cover [1] from the switch compartment.
Close
2. Clean sealing faces of housing and cover.
3. Preserve joint surfaces with an acid-free corrosion protection agent.
4. Check whether O-ring [3] is in good condition, replace if damaged.
5. Apply a thin film of non-acidic grease (e.g. petroleum jelly) to the O-ring and
insert it correctly.
6. Place cover [1] on switch compartment.
7. Fasten screws [2] evenly crosswise.
10.2. Mechanical position indicator (self-adjusting)
Figure 63: Mechanical position indicator (self-adjusting)
The self-adjusting mechanical position indicator shows the valve position by means
of an arrow . When correctly set, the arrow points to symbol (OPEN) or
(CLOSED) in the end positions.