10
EN
Aura Allure with Xena Click & Tan
Prolonged hot baths and showers should be avoided in order to maintain the tanning
effect for as long as possible. Daily moisturization of the skin is also recommended.
14. Taking Out of Operation and Cleaning
i
Clean the Spray Tanning System as required, at the end of the working day/
application. Dried spray tanning lotion makes cleaning more dicult and can
even damage the system.
1) Turn the system o.
2) Unscrew the container.
3)
Pour any remaining spray tanning lotion
back into the original packaging.
4) Clean the container and feed tube with
a brush.
5) Remove the pick up tube (g. 10,2) and
container seal (g. 10,1)
6) 6) Dry underneath the seal before re-
inserting. A spare pick up tube and seal
comes with your unit. Re-insert both
parts. Make sure the seal is pushed
down so that all the air is removed
from underneath the seal.
Do not use ammable materials for
cleaning purposes.
7) Dry the threading of the container and
gun before screwing the container back
on.
8)
Repeat the above procedure until the
water emerging from the nozzle is clear.
9) Turn the system o.
10) For a more thorough clean, unscrew the
container and empty. Again remove the
pick up tube with container seal.
CAUTION! NEVER clean seals, nozzles or
air holes of the spray gun with
metal objects or chemical
cleaners.
11) Unscrew the union nut/ air cap ring and
remove the air cap and nozzle (Fig. 11).
Clean the air cap, nozzle seal and nozzle
with a brush and water.
12) Clean the outside of the spray gun and
container with a cloth soaked in water.
13)
Dry all parts before re-assembling (see
Assembly”).
1
10
2
11