5.3 Electrical connection
The MBC930D battery charger can be powered by a 12/24V battery or by a power supply
unit equipped with safety isolating transformer.
Never use the battery charger if it is damaged.
Make sure that power supply provided by a 12/24V battery or by a power
supply unit equipped with safety isolating transformer is protected against
short circuit.
Check that the Battery Charger power supply voltage is within the limits
given in the “Technical data”.
The power supply cable of the MBC930D battery charger cannot be longer
than two meters.
If the supply cable cannot be unplugged (by way of example: unmovable
connection to a battery), an easily accessible switch shall be provided, to
allow power supply disconnection. If, on the other hand, the supply cable
can be unplugged ( by way of example: plug at the end of the cable) it shall
always be easily accessible.
It is good practice to connect the battery charger to the power source only when
recharging the battery. Once the charging has been completed, disconnect the
battery charger from the power supply.
5.4 Positioning
Place the Battery Charger in an indoor and dry place, far from liquids, dust
and heat sources.
Leave at least 5cm (1.97In) room above and around the Battery Charger.
Do not set any objects on the Battery Charger when it is connected to the
mains.
Do not in any case perforate, modify or tamper with the Battery Charger.