TECHNICAL SPECIFICATIONS
INPUT VOLTAGE: 230V- 240V AC 50Hz
(Other voltages available upon request
e.g. 110V AC 60Hz)
TRANSFORMER PRIMARY VOLTAGE: 230V / 240VAC
SECONDARY VOLTAGE: 24V AC 100 VA
CONTROLLER VOLTAGE: 24V DC
MAXIMUM DOOR OPENING:
1,2
WIDTH: 5100mm
HEIGHT: 3100mm
RATED LOAD: 200N
OPENER OPENING/CLOSING LIMITS TRAVEL: 3.5 Turns of Door Drum Wheel
OPENER MAXIMUM
OPENING/CLOSING RUN TIME: 30 Secs.
RECEIVER TYPE: UHF 433.92 MHz. AM Receiver
RECEIVER CODE STORAGE CAPACITY: 23 x 4 Button Transmitter Codes
TRANSMITTER FREQUENCY: 433.92 MHz
CODING TYPE: Code Hopping
No. of CODE COMBINATIONS: Over 4.29 Billion Random Codes
CODE GENERATION: Non-linear Encryption Algorithm
PTX-4 TRANSMITTER BATTERY: A23 Alkaline 12 Volts
EAT-1 TRANSMITTER BATTERY: CR1220 Lithium 3 Volts
MOTOR TYPE: Permanent Magnet Direct Current
MOTOR VOLTAGE: 24V DC
GLOBE: Festoon Type - 15w 24V DC
SPECIFICATIONS AND DEFAULT SETTINGS
20
Note:
1. The maximum continuos curtain domestic roll up door opening that the EasyRoller can be installed on is 5100mm wide by 3100mm
high The door must be well balanced. A person should be able to lift the door up manually with very little effort in case of an
emergency.
2. Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra pressure on the door
and tracks which may in turn trigger the safety obstruction detection system intermittently.
DEFAULT STEP MAXIMUM
MAXIMUM MOTOR RUN TIME 30 Secs.
COURTESY LIGHT TIME 3 Mins. 10 Secs. 4 Mins.
OBSTRUCTION FORCE MARGIN 4 1 14
AUTO CLOSE TIME 0 Secs. 1 Sec. 4 Mins.
FACTORY DEFAULT SETTINGS