6
OPERATING CONTROLS
LIGHT CODE button (white) is
used for storing or erasing the
transmitter button (code) you wish
to use to switch the opener’s cour-
tesy light on and off.
CODING LED (red) light flashes
when a code is being stored or
when a transmitter button is
pressed.
DOOR CODE button (blue) is
used for storing or erasing the
transmitter button you wish to use
to command the door to open, stop
or close.
P. E. SHUNT. The shunt has to be
removed when connecting a Photo
Electric Beam.
NOTE: P.E. SHUNT must not be
removed otherwise the opener will
not function correctly. Remove
only when a P.E beam is to be
connected.
RX INPUT is used for the
connection of an external receiver.
The receiver input can supply
30mA at 24 volts DC maximum to
power an external receiver.
PROG INPUT is used for the
connection of the ATA Universal
Programmer for the purpose of
editing control and receiver
functions.
CLOSE drive button (red) is used
during installation to help set the
close limit position. Pressing and
holding this button will move the
door in the close direction.
Movement stops when the button
is released.
NOTE: The close safety
obstruction detection is
inoperable whenever the Close
Drive button is used to move
door.
1.
2.
3.
4.
6.
7.
8.
CLOSE LIMIT LED (red) the led
is very helpful during installation.
It illuminates and flashes when the
door is closing and remains steady
on when the close limit position
has been reached.
O/S/C INPUT is used for the
connection of a wired switch
(momentary contact). This switch
can then be used to open, stop or
close the door. Install the wall
switch in a location where the
switch is out of reach of children
and the garage door is visible.
AUTO CLOSE TIME button
(White) is used to adjust the auto
close time. While holding in the
auto close button and then pressing
the open button the time is
increased. Each press will increase
the time by 5 seconds. Pressing the
close button will decrease the time.
MOTOR CONNECTOR is used
to select the direction of rotation of
the Motor. The connector has to be
moved left or right depending on
which side of the Roll Up Door
the Opener is to be installed.
BATTERY CHARGER INPUT
is used for the connection of a
battery charger.
FORCE MARGIN SET The
obstruction force pressure is set
automatically by the opener during
installation. The pressure can be
adjusted manually using the Force
Margin Set button (White).
Pressing the force margin set
button and open or close button
will increase or decrease the
amount of force. The Force Margin
Set is only ever used if other
environmental factors (wind, etc.)
effect the operations of the
door/opener.
9.
10.
11.
12.
13.
14.
OPEN LIMIT LED (green) the
led is very helpful during
installation. It illuminates and
flashes when the door is opening
and remains steady on when the
open limit position has been
reached.
OPEN DRIVE button (green) is
used during installation to help set
the open limit position. Pressing
and holding this button will move
the door in the open direction.
Movement stops when the button
is released.
NOTE: The open safety
obstruction detection is
inoperable whenever the Close
Drive button is used to move
door.
O/S/C button (Yellow) is used
during installation to test the open,
stop and close cycles for the
opener. The opener has to be
initialised by the Reset button
before the O/S/C button becomes
operable.
SET button (yellow) is used
during the installation phase
together with the Open and Close
buttons to set the door limit
positions. The Set button is also
used to re-initialise the Opener.
ENGAGE/DISENGAGEMENT
CORD when pulled down and
released this will select manual
mode on the opener, particularly
when there is a power failure.
Pulling down and again releasing
will select automatic mode on the
opener. The length of the string is
adjustable.
EASY ACCESS
TRANSMITTER The
“manual
release”
engage/disengagement
handle has within its housing a
wireless transmitter. If the button
is pressed it will open, stop or
close the garage door.
15.
16.
17.
18.
19.
20.