EasyManua.ls Logo

Automatic Technology SECURALIFT - Technical Specification; Door Status Indicators; Specification; Factory Set Defaults

Automatic Technology SECURALIFT
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DEFAULT STEP MAXIMUM
MAXIMUM MOTOR RUN TIME 30 Sec. _ _
COURTESY LIGHT TIME 3 Min. 10 Sec. 10 Min.
OBSTRUCTION FORCE MARGIN 4 1 16
AUTO CLOSE TIME 0 Sec 5 Sec. 4 Min.
FACTORY SET DEFAULTS
INPUT VOLTAGE:
230 V / 240 V AC 50 Hz
OPENER PUSHING / PULLING
FORCE
300 N
RECEIVER TYPE
UHF 433.92 MHz AM Receiver
Receiver Code Capacity
27 X 4 Transmitter Codes
TRANSMITTER
Frequency
Coding Type
Number of Code Combinations
Code Generation
Battery Voltage
433.92 MHz
Hopping Code
Over 4.29 Billion Hopping Codes
Non-linear Encryption Algorithm
12 Volts
TECHNICAL SPECIFICATIONS
16
DOOR STATUS INDICATORS.
DOOR OPENER STATE OPEN LED
GREEN
CLOSE
LED
RED
SERVICE
LED
YELLOW
COURTESY
LIGHT
BEEPER
OPEN On
CLOSE On
OPENING Flashing
CLOSING Flashing
DOOR TRAVEL STOPPED Flashing Flashing
DOOR OBSTRUCTED WHEN OPENING Flashing Beeps on and off
DOOR OBSTRUCTED WHEN
CLOSING
Flashing Beeps on and off
DOOR OVERLOADED Flashes ten times Beeps on and off
DOOR AND OPENER REQUIRE A SER-
VICE
Flashing Beeps at the start of any
cycle
DOOR AND OPENER APPROACHING
OVERLOAD
Beeps for the duration
of the time approaching
overload
DOOR HAS APPROACHED OVERLOAD
THREE TIMES IN EIGHT CYCLES
On Beeps at the start of any
cycle
DOOR IN OPEN POSITION WITH AUTO
CLOSE MODE SELECTED
One second
flashes
MAINS POWER INTERRUPTED TO
OPENER
Rapid flashes

Related product manuals