B-30
BF4 Series
Features
High reliability of fiber optic amplifier for convenient mounting
● High speed response : Max. 0.5ms
Auto sensitivity setting(Button setting)/Remote sensitivity setting
● External synchronization input, mutual interference protection, self-diagnosis
● Reverse power polarity and short-circuit(Overcurrent) protection circuit
● Timer function : Selectable None / 40ms OFF Delay timer(xed)
(Standard type, remote sensitivity setting type only)
Automatically selectable Light ON / Dark ON
● Precise detection of small target and complicated place to install
1: Frequency 1(Normal mode) : Max. 0.5ms, Frequency 2 : Max. 0.7ms
The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.
Model
Standard type
External synchronization
input type
Remote sensitivity
setting type
BF4RP BF4GP BF4R BF4G BF4R-E BF4G-E BF4R-R BF4G-R
Response frequency Max. 0.5ms(Frequency 1), Max. 0.7ms(Frequency 2)
Power supply 12-24VDC ±10%(Ripple P-P: Max.10%)
Current consumption Max. 45mA
Light source
(modulated light)
Red Green Red Green Red Green Red Green
Sensitivity adjustment Sensitivity adjustment button(ON/OFF)
Operation mode Automatic selection of Light ON/Dark ON accordance with button setting
Control output
NPN or PNP open collector output
● Load voltage: Max. 30VDC ● Load current: Max. 100mA
● Residual voltage - NPN: Max. 1V(load current: 100mA), Max. 0.4V(load current:16mA) / PNP: Max. 2.5V
Self-diagnosis output
ON state under unstable sensing(When the target stays for 300ms in unstable area),
ON state when control output short-circuited
● Load voltage: Max. 30VDC ● Load current: Max. 50mA
● Residual voltage - NPN: Max. 1V(load current: 50mA), Max. 0.4V(load current:16mA) / PNP: Max. 2.5V
Protection circuit Reverse power polarity, short-circuit(overcurrent) protection circuit
Indicator Operation indicator : Red LED, Stability indicator : Green LED ON when the target stays in stable sensing level
Input of stop
transmission function
-
Built-in
-
External synchroniza-
tion function
-
Built-in(Gate/Trigger)
-
Remote sensitivity
setting function
- -
Built-in
Interference
prevention function
1
Built-in differential frequency mode (set by frequency 1 or 2 by ON/OFF button)
Timer function
(selectable)
Built-in OFF delay timer, Approx. 40ms xed
-
Built-in OFF delay timer
, Approx. 40ms xed
Ambient illumination Sunlight : Max. 11,000
, Incandescent lamp : Max. 3,000
㏓(Receiver illumination)
Noise resistance ±240V the square wave noise(pulse width : 1
) by the noise simulator
Dielectric strength 1,000VAC 50/60Hz for 1 minute
Insulation resistance Min. 20MΩ(at 500VDC megger)
Vibration 1.5mm amplitude or 300m/s
2
at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 2 hours
Shock 500m/s²(approx. 50G) in each of X, Y, Z directions for 3 times
Environ-
ment
Ambient
illumination
Sunlight : Max. 11000
, Incandescent lamp : Max. 3000
(received illumination)
Ambient
temperature
-10 to 50
℃,
storage : -20 to 70
Ambient
humidity
35 to 85% RH, storage :35 to 85% RH
Material Case : Heat-resistance ABS, Cover : PC
Cable
Ø4, 4-wire, Length: 2m
(AWG22, Core diameter: 0.08mm, Number of cores: 60,
Insulator out diameter : Ø1.25mm)
Ø4, 6-wire, Length: 2m
(AWG24, Core diameter: 0.08mm, Number of cores: 40,
Insulator out diameter : Ø1mm)
Accessory Mounting bracket, Bolts/nuts
Approval
Unit weight Approx. 65g
Specifications
Please read “Caution for your safety” in operation
manual before using.

Other manuals for Autonics BF4G

Question and Answer IconNeed help?

Do you have a question about the Autonics BF4G and is the answer not in the manual?

Autonics BF4G Specifications

General IconGeneral
BrandAutonics
ModelBF4G
CategoryAccessories
LanguageEnglish

Related product manuals