J-25
LCD Display Counter/Timer
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
Parameter Setting (Timer)
(
key: moves parameters,
key: changes parameter setting value)
1: This is for the voltage input (PNP)/no-voltage input (NPN) selectable model (CX6 - ).
2:
INt2
mode is available only for 2-stage setting model(CX6 -2P ).
3: When output mode is
OND
,
ONd1
,
ONd2
,
ONd3
,
FLk1
,
FLk2
,
INT
,
INt1
,
INt2
,
OFD
,
INTG
,
TOTAL
,
ONtD
, set time range [
tRNG
].
4: When output mode is
FLK
,
NFD
,
NFD.1
, set output ON TIME range [
OnRNG
] and output OFF TIME range [
OFfRNG
].
5: In case of 1-stage setting model (CX6 -1P
)
,
OUT1
output time does not appear.
OUT2
output time is displayed as
OUtT
.
6: In case of free voltage input model (CX6
-
F), this parameter does not appear due to fixed setting.
Parameter Parameter setting value
Counter/Timer
[
C-T
]
COUNT
TIME
COUNT
: Counter
TIME
: Timer
Up/Down mode
[
U-D
]
UP DN
UP
: Time progresses from '0' to the setting time.
DN
: Time progresses from the setting time to '0'.
Output mode
[
OUt
M
]
OND
TOTAL
1
ONtD INTG NFd1 NFD OFD INt2
2
INt1
FLk1 FLk2 INTFLKONd1 ONd3ONd2
Time range
[
tRNG
]
3
m:s
m:s
s s s
TIMER
s
999
.
999
TIMER
9999
.
99
TIMER
99999
.
9
TIMER
m
99999
.
9
TIMER
h
99999
.
9
TIMER
m
999999
TIMER
m:s
99
:
59
.
99
TIMER
h:m:s
99
:
59
:
59
TIMER
999
:
59
.
9
TIMER
9999
:
59
TIMER
h:m
9999
:
59
TIMER
999999
output ON TIME range
[
OnRNG
]
4
,
output OFF TIME range
[
OFfRNG
]
4
OUT 2 output time
5
[
OUT2
]
Set one-shot output time of OUT 2.
Setting range: 00.01 to 99.99 sec, Hold
When number of tens digit is ashing, press the key once and
HOLD
appears.
OUT 1 output time
5
[
OUT1
]
Set one-shot output time of OUT 1.
Setting range: 00.01 to 99.99 sec, Hold
When number of tens digit is ashing, press the key once and
HOLD
appears.
OUT output time
5
[
OUtT
]
Setting range: 00.01 to 99.99 sec, Hold
When number of tens digit is ashing, press the key once and
HOLD
appears.
Input logic
6
[
SIG
]
NPN
: No-voltage input,
PNP
: Voltage input
Input signal time
6
[
IN
-T
]
1 20
, unit: ms
Set min. width of INA, INHIBIT, RESET, TOTAL RESET signal
Memory protection
[
DATA
]
CLR REC
CLR
: Resets the counting value when power OFF.
REC
: Maintains the counting value when power OFF. (memory protection)
Key lock
[
LOCK
]
lOFF LOc1
LOc3 LOc2
lOFF
: Unlock keys, key lock indicator turns OFF
LOc1
: Locks
RESET
key, key lock indicator turns ON
LOc2
: Locks , keys, key lock indicator turns ON
LOc3
: Locks
RESET
, , keys, key lock indicator turns ON

Other manuals for Autonics CX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Autonics CX Series and is the answer not in the manual?

Autonics CX Series Specifications

General IconGeneral
BrandAutonics
ModelCX Series
CategoryTimer
LanguageEnglish

Related product manuals