Parameter Setting (Timer)
(
key: moves parameters,
key: changes parameter setting value)
※
1: This is for the voltage input (PNP)/no-voltage input (NPN) selectable model (CX6 - ).
※
2:
INt2
mode is available only for 2-stage setting model(CX6 -2P ).
※
3: When output mode is
OND
,
ONd1
,
ONd2
,
ONd3
,
FLk1
,
FLk2
,
INT
,
INt1
,
INt2
,
OFD
,
INTG
,
TOTAL
,
ONtD
, set time range [
tRNG
].
※
4: When output mode is
FLK
,
NFD
,
NFD.1
, set output ON TIME range [
OnRNG
] and output OFF TIME range [
OFfRNG
].
※
5: In case of 1-stage setting model (CX6 -1P
)
,
OUT1
output time does not appear.
OUT2
output time is displayed as
OUtT
.
※
6: In case of free voltage input model (CX6
-
F), this parameter does not appear due to fixed setting.
Parameter Parameter setting value
Counter/Timer
[
C-T
]
COUNT
TIME
※
COUNT
: Counter
TIME
: Timer
Up/Down mode
[
U-D
]
UP DN
※
UP
: Time progresses from '0' to the setting time.
DN
: Time progresses from the setting time to '0'.
Output mode
[
OUt
M
]
OND
TOTAL
※
1
ONtD INTG NFd1 NFD OFD INt2
※
2
INt1
FLk1 FLk2 INTFLKONd1 ONd3ONd2
Time range
[
tRNG
]
※
3
m:s
m:s
s s s
TIMER
s
999
.
999
TIMER
9999
.
99
TIMER
99999
.
9
TIMER
m
99999
.
9
TIMER
h
99999
.
9
TIMER
m
999999
TIMER
m:s
99
:
59
.
99
TIMER
h:m:s
99
:
59
:
59
TIMER
999
:
59
.
9
TIMER
9999
:
59
TIMER
h:m
9999
:
59
TIMER
999999
output ON TIME range
[
OnRNG
]
※
4
,
output OFF TIME range
[
OFfRNG
]
※
4
OUT 2 output time
※
5
[
OUT2
]
※
Set one-shot output time of OUT 2.
※
Setting range: 00.01 to 99.99 sec, Hold
※
When number of tens digit is ashing, press the key once and
HOLD
appears.
OUT 1 output time
※
5
[
OUT1
]
※
Set one-shot output time of OUT 1.
※
Setting range: 00.01 to 99.99 sec, Hold
※
When number of tens digit is ashing, press the key once and
HOLD
appears.
OUT output time
※
5
[
OUtT
]
※
Setting range: 00.01 to 99.99 sec, Hold
※
When number of tens digit is ashing, press the key once and
HOLD
appears.
Input logic
※
6
[
SIG
]
NPN
: No-voltage input,
PNP
: Voltage input
Input signal time
※
6
[
IN
-T
]
1 20
, unit: ms
※
Set min. width of INA, INHIBIT, RESET, TOTAL RESET signal
Memory protection
[
DATA
]
CLR REC
※
CLR
: Resets the counting value when power OFF.
REC
: Maintains the counting value when power OFF. (memory protection)
Key lock
[
LOCK
]
lOFF LOc1
LOc3 LOc2
※
lOFF
: Unlock keys, key lock indicator turns OFF
LOc1
: Locks
RESET
key, key lock indicator turns ON
LOc2
: Locks , keys, key lock indicator turns ON
LOc3
: Locks
RESET
, , keys, key lock indicator turns ON