Default
Alarm output1 Operation
AL-1 DVCC
Alarm output1 Option AL!T AL-A
A!HY 001
Alarm output1 contact
A!N NO
time
A!ON 0000
time
A!OF 0000
Alarm output2 Operation
AL-2 ]]DV
Alarm output2 Option AL@T AL-A
A@HY 001
Alarm output2 contact
A@N NO
time
A@ON 0000
time
A@OF 0000
AL-3 OFF
AL#T AL-A
A#HY 001
A#N NO
time
A#ON 0000
time
A#OF 0000
LBA time LBaT 0000
LBaB
002
003
Analog Transmission
AoM1 PV
Transmission output1
FsL1 -200
Transmission output1
high limit
FsH1 1350
Analog Transmission
AoM2 PV
Transmission output2
FsL2 -200
Transmission output2
high limit
FsH2 1350
ADRS 01
BPS 96
PRTY NONE
STP 2
Response time RSWT 20
COMW EnA
Default
Multi SV MtSV 1
DI-K STOP
Digital input1 Terminal
DI-1 OFF
Digital input2 Terminal
DI-2 OFF
ItMV AUTO
MV
PrMV 00)0
Sensor error MV ErMV 00)0
Control stop MV StMV 00)0
Control stop alarm
output
StAL CONT
User level USER STND
SV setting lock LcSV OFF
Parameter 1 group lock LcP1 OFF
Parameter 2 group lock LcP2 OFF
LcP3 OFF
Parameter 4 group lock LcP4 OFF
Parameter 5 group lock LcPS OFF
PWD 0000
Default
Control output
R-S RUN
Multi SV selection SV-N SV-0
Heater current
monitoring
CT-A )0
AL!L 1550
Alarm output1 high limit AL!H 1550
AL@L 1550
Alarm output2 high limit AL@H 1550
AL#L 1550
AL#H 1550
Multi SV 0 SV-0 0000
Multi SV 1 SV-1 0000
Multi SV 2 SV-2 0000
Multi SV-3 0000
Default
AT OFF
Heating proportional
H-P 01)0
Cooling proportional
C-P 01)0
Heating integral time H-1 0000
Cooling integral time C-1 0000
H-D 0000
C-D 0000
DB 0000
Manual reset REST 05)0
hHYS 002
hOST 000
cHYS 002
cOST 000
L-MV `0)0
MV high limit H-MV 10)0
RAMP up change rate RAMU 000
RAMD 000
RAMP time unit rUNT MIN
Default
IN-T KCaH
Temperature unit UNIT ><?C
L-RG 0)00
Analog high limit H-RG 1)00
DOT )0
L-SC 00)0
High limit scale H-SC 10)0
dUNT >?/O
Input correction IN-B 0000
MAvF 00)1
L-SV -200
SV high limit H-SV 1350
O-FT
HEAT
H-C
Cooling
C-MD
PID
pP
Cooling-
AtT TUN1
OUT1 control output
selection
OUT1 CURR
O!SR STND
OUT1 current output
range
O!MA 4-20
OUT2 control output
selection
OUT2 CURR
OUT2 current output
range
O@MA 4-20
H-T
02)0
00@0
C-T
•
•
•
88* 8
Alarm
Alarm
•
Name
No alarm output
Deviation
high limit
SV
100
PV
110
ON
PV
SV
100
ON
SV as high-limit is higher
Deviation
PV
SV
100
ON
SV
100
PV
110
ON
Deviation
limit
PV
PV
110
SV
100
ON ON
Deviation
limit reverse
PV
PV
110
SV
100
ON
value high
limit
PV
SV
100
ON
SV
100
PV
110
ON
limit
PV
SV
100
ON
SV
100
PV
110
ON
Name
Condition
alarm
-
Alarm latch
-
Alarm
change
alarm
temperature
or change
STOP to RUN
Alarm