AUTOOL BST-100 Battery System Tester User Manual
2
the actual required cranking current and cranking voltage of the starting motor,
it can find out whether the starting motor works fine. There are several reasons
why the starting motor is abnormal: lubricating system fault causing the
starting loaded torque increasing or rotor friction of the starting motor causing
the increasing friction of the starting motor itself.
Charging test is to check and analyze the charging system, including
generator, rectifier, rectifier diode, etc., thus to find out whether the output
voltage of the generator is normal, the rectifier diode works fine and the
charging current is normal. Suppose one of the above mentioned parts is not in
normal situation, it will lead to over charge or incomplete charge of the battery,
thus the battery will be quickly damaged and also greatly shorten the using life
of other loaded electrical appliance.
Additional functions include: Set language, voltmeter and screen brightness
adjustment.
1.3 Technical Parameters
1. Cold Cranking Amps Measure Range:
Measure Standard Measure Range
CCA 100-800
JIS 26A17--245H52
DIN 100-700
IEC 100-700
EN 100-800
SAE 100-800
GB 100-700
2. Voltage Measure Range: 6-30VDC