7.6 REVIEW OF INSTALLER, OWNER, & MAINTENANCE MENU PROGRAMMING
Note: Once determined to be appropriately programmed for the installation site, the following menu
items should not require regular access. See “Basic Operational Programming” on page 20 for setting
the initial Chlorine Level and routine control instructions.
7.6.1 Set Pool Volume
The pool volume must be programmed for the “Add salt ### lb (kg)” display to be
accurate.
1) Press MENU, press or until “Installer menu” is displayed; then press and hold
SELECT for 13 seconds.
2) Press or until “Set pool volume” is displayed; then press SELECT.
3) Factory setting is 15,000 gallons (60,000 Liters). The range is 500 to 125,000 gallons
(2,000 to 500,000 Liters).
4) Press or until correct pool size is displayed; then press SELECT.
5) Press or until “End menu mode” is displayed; then press SELECT.
7.6.2 Calibrate Salt
Note: The unit has been calibrated at the factory and should not require further adjustments. In
the event the salt display does not match on-site test results, follow these steps (it is necessary
to wait 2 minutes after water flow has started before calibrating salt):
1) Press MENU, Press or until “Maintenance Menu” is displayed; then press
SELECT.
2) Press or until “Calibrate salt” is displayed; then press SELECT.
3) Press or until the number on the display matches the accurately measured pool
sample; then press SELECT. The maximum adjustment is ± 1,000 ppm (mg/L).
4) Press or until “End menu mode” is displayed; then press SELECT.
7.6.3 Select Language
Allows for personal preference language display.
1) Press MENU, press or until “Owner options” or “Installer menu” is
displayed; then press SELECT.
2) Press or until “Select language” is displayed; then press SELECT (English is
the factory setting).
3) Press or until desired option “English language” “Idioma Español,”
“Langue Francaise,” “Deutsche sprache”, “Lingua Italiana” or “Cesky
Jazyk” is displayed; then press SELECT.
4) Press or until “End menu mode” is displayed; then press SELECT.
7.6.4 Calibrate Temperature
Note: Temperature can only be calibrated 2 minutes after start-up. Used only when it is desired
to match the display of the Digital Nano/Nano+ to another on-site thermometer.
1) Press MENU, Press or until “Maintenance menu” is displayed; then press
SELECT.
2) Press or until “Calibrate temp.” is displayed; then press SELECT.
3) Press or to adjust temperature UP or DOWN to the desired temperature; then
press SELECT. The maximum adjustment is ± 6°F (± 3°C).
4) Press or until “End menu mode” is displayed; then press SELECT.