Page 38
8.9 PROGRAMMING AT INSTALLATION
The Digital Nano/Nano+ requires the pool volume be initially programmed into the installer menu. The
Digital Nano/Nano+ will then indicate how many pounds (kgs) of salt to add should salt levels fall. The
default pool size is 15,000 gallons (60,000 liters). The Salt Addition Chart on page 52 can also be used
to calculate how much salt in pounds (kgs) should be added to reach the recommended level of 3,000-
4,000 ppm (mg/L) salinity.
1) Enter the Installer menu and program "Set pool volume" for specific pool. See
Calculating Pool Volumeon page 36.
a) Press MENU
b) Press or until “Installer menu” is displayed;
c) Press and hold SELECT for 13 seconds to enter the Installer menu
d) Press or until “Set pool volume” is displayed; then press SELECT.
Factory setting is 15,000 gallons (60,000 liters).
The range is 500 to 125,000 gallons (2,000 to 500,000 liters).
e) Press or until correct pool size is displayed; then press SELECT.
f) Press or until “End menu mode” is displayed; then press SELECT.
2) Configure the following as needed. See Section 7.6, Review of Installer, Owner, &
Maintenance Menu Programming on page 23 for more information.
a) "Select language" (English language”, Idioma Español” “Langue
Francaise” “Deutsche sprache”, “Lingua Italiana” or “Cesky Jazyk”)
b) "Select units (gallons/liters, lb/kg, ppm/mg/L)
c) Temperature units" (°F or °C)
d) Audio alarm” (On or Off)
e) Display temp” (“Hide temperature” or Show temperature”)
3) Press or to adjust chlorine output to 50%.

Table of Contents