Page 26
3) Press or until the desired cycle time (2, 4, 8, or 16 hours) is displayed; then press
SELECT.
4) Press or until “End menu mode” is displayed; then press SELECT.
7.6.12 Force Reverse
Note: This is a diagnostic tool only, and should not be used unless a problem is suspected.
Program the cell to activate a Force Reverse cycle and verify if the system is reversing polarity
(self-cleaning). There will be a 40 second delay, after selecting “End menu mode”, before
reversing takes place.
1) Press MENU, press or until “Maintenance menu” is displayed; then press
SELECT.
2) Press or until “Force reverse” is displayed; then press SELECT.
3) “Cell reversing” will display temporarily in 40 seconds.
4) Press or until “End menu mode” is displayed; then press SELECT.
5) The “.” (period) on the end of 2nd line of the display will either appear, or disappear—
based on its previous state—to indicate cell power polarity has reversed.
7.6.13 Enable/Disable Audio Alarm
Note: If alarm is due to low or no water flow, the Audio Alarm will automatically silence in
10 minutes. Upon restoration of flow, normal Audio Alarm operation will resume.
1) Press MENU, press or until “Owner options” or “Installer menu” is
displayed; then press SELECT.
2) Press or until “Audio alarm” is displayed; then press SELECT.
3) Press or until “On or off” is displayed; then press SELECT.
4) Press or until “End menu mode” is displayed; then press SELECT.
7.6.14 Select System (Optional Feature w/ 863A Expansion Board)
Used by the installer to set the basic equipment configuration of the system.
1) Press MENU, press or until “Installer menu” is displayed, then press and hold
SELECT for 13 seconds.
2) Press or until “Select system” is displayed, then press SELECT (Purifier is the
factory setting). The display will show the current configuration.
3) Press or until “Purifier” is displayed, then press SELECT.
4) Press or until “End menu mode” is displayed; then press SELECT.
If the optional 863A Expansion Board has been installed, additional options will be displayed
that are not supported with this model. Do not choose “pH Timed”, “pH Probe” or “Total
Control”: