1. Enter Test Pool Pilot mode through the menu.
Write down the salt level, water temperature, and
cell volts and amps.
If the volts are 24-26, then the problem is usually
caused by low salt, improperly connected,
disconnected or loose cell cord, water less than
65°F (18.3°C), a scaled cell, or cell near end of life.
Correct as appropriate.
If the volts are less than 20, then contact AquaCal
AutoPilot, Inc. for assistance.
2. Installer: If the unit is configured for 230 Vac
operation, then verify the input AC voltage is not
115 Vac. Supply correct voltages or reconfigure the
unit as appropriate.
1. Check cell for calcium scale buildup. Clean as
needed.
2. Check cell for wire or other debris that is shorting
the electrodes.
1. Check the Tri-sensor cable; make sure it is not
disconnected or loose.
2. Check the water temperature.
If confirmed temperature is OK, contact AquaCal
AutoPilot, Inc. for assistance.
All 3 messages must be displayed for this to be a
control unit problem. Contact AquaCal AutoPilot,
Inc. for service.
If all 3 messages are not being displayed then refer
to the specific individual fault message above.