Page 49
CHEMICAL
IDEAL
TEST
SCHEDULE
EFFECT OF
LOW / HIGH LEVELS
CORRECTIVE ACTIONS
Calcium
Hardness
Monthly
Low CH: Etching of plaster, equipment
corrosion
Low CH: Add calcium chloride flakes.
High CH: Scale formation, cloudy water.
Rapid buildup of scale may exceed the
system's self-cleaning capability and require
manual cleaning of the cell.
High CH: Partially drain and refill pool with
fresh water to dilute. (Diluting will reduce salt
and CYA. Check and adjust as needed.)
Cyanuric Acid
(CYA or
Stabilizer)
Monthly
Low CYA: Destruction of chlorine by the UV
rays from the sun.
Low CYA: Add Cyanuric acid
(1 lb.(0.45 kg) per 5,000 gallons (18,930
liters) increases CYA 25 ppm (mg/L))
High CYA: Requires more chlorine to
maintain proper sanitizer levels. Note: CYA
not needed for indoor pools or bromine
pools. CYA can be reduced to 30 - 50 ppm
(mg/L) for colder climate regions.
High CYA: Partially drain and refill pool with
fresh water to dilute. (Diluting will reduce
salt. Check and adjust as needed.)
Saturation
Index
Monthly
+ 0.3: Water is scale forming. Calcium
carbonate is falling out of solution.
This rapid buildup of scale may exceed the
system's self-cleaning capability and require
manual cleaning of the cell.
Balance water as close to equilibrium of 0 as
possible. See Basic Water Chemistry” on
page 51 for more information.
- 0.3: Water is corrosive. Water will take
away other material it comes in contact with
to form a natural balance. These materials
can be metallic fixtures, swimwear, etc.
Results can also include cloudy water,
eye/skin irritation, and poor chlorine
effectiveness.
Balance water as close to equilibrium of 0 as
possible. See Using the Saturation Index
on page 51 for more information.
Salt
Monthly
Low Salt: Below 2,400 ppm (mg/L) causes
premature cell failure and reduces chlorine
production
Low Salt: Add salt according to digital display
on Pool Pilot
®
unit or salt chart.
High Salt: Above 6,000 ppm (mg/L) can
cause corrosion of metallic fixtures and will
taste salty. Note: Digital Nano/Nano+ can
safely operate with salt levels up to 35,000
ppm (mg/L).
High Salt: If undesirably high, partially drain
and refill the pool with fresh water. (Diluting
will reduce CYA. Check and adjust as
needed.)
Table 7