17
Specifications
SpecificationsSpecifications
Specifications
Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 to 132 VAC, 60 Hz
Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA
Operating Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 to 120
o
F (1 to 49
o
C)
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 to 100% condensing allowed
Water Meter Accuracy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 to 23 gpm (1.9 to 87 Lpm)
Note:
Wall-mount transformer is rated for indoor use only.
Glossary of Terms
Glossary of TermsGlossary of Terms
Glossary of Terms
Alarms
Alarms are beeps which alert you to operating
conditions requiring attention. The beeps are on for one
second and off for nine seconds. The display shows the
type of error. Refer to the
Alarms
section in this manual
for additional information.
Backwash
An upward flow of water which expands the resin bed
to remove foreign particles.
Brine
The salt solution which regenerates the conditioner’s
resin bed.
Brine Draw
The process of drawing the brine solution from the salt
storage tank into the resin tank.
Calendar Override Regeneration
If a normal demand-based regeneration does not
occur, the Model 960 Control regenerates the system
after a preset number of days. Your dealer can set this
feature at one to 30 days.
Fast Rinse (Purge)
A flow of water through the resin bed which propels any
remaining brine solution out of the resin tank to the
drain.
Hardness
A common quality of water containing dissolved
calcium, magnesium and other elements. Water
hardness is usually expressed in grains per gallon or
milligrams per liter as calcium carbonate equivalent.
Manual Regeneration (Guest Cycle)
Forces the control to regenerate by pressing the
REGEN button.
Regeneration
Includes the backwash, brine draw, and fresh water
rinse steps necessary to prepare the resin bed for
conditioning after exhaustion. Abbreviated as
“REGEN” in this manual.
Regeneration Indicator
The mechanical component which indicates the
regeneration cycle status.
Resin Bed
The supply of synthetic organic ion exchange material
used in water conditioners.