5
next number starts flashing. You can only change
the flashing number.
4. Continue changing numbers until you reach the
desired setting.
5. Press the
SET
button. The number stops flashing
and the control accepts the new setting. After
approximately 30 seconds, the control starts
alternating the display between TIME OF DAY and
CAPACITY.
Note:
If a beep sounds, the new setting is not
accepted.
Reminder:
The control does not keep time during a
power outage but will resume its time, keeping from the
time of day power was lost. A short power outage
should not cause a problem. If the outage is several
hours, the control will regenerate at the wrong time of
day. All other memory is stored in the NOVRAM and
maintained during power outage. Refer to page 3.
Time of Regeneration
The control uses the Time of Regeneration to decide
when to begin a regeneration. When a regeneration is
necessary and the Time of Day clock is at the same
time as the Time of Regeneration setting, the control
starts regeneration. The factory setting for Time of
Regeneration is 2:00 a.m. If this time is inconvenient,
you can select any other time of day. Remember that
soft water is not available during a regeneration of the
water conditioner. Time of Regeneration can be set for
any time, a.m. or p.m.
Note:
The control may be programmed for an
immediate regeneration option. In this case, the control
does not wait for the Time of Regeneration but
regenerates when the remaining capacity reaches zero.
Contact your dealer for more information regarding this
option.
Complete the following steps to change the Time of
Regeneration:
1. Press the down arrow [↓] button until the green light
next to the TIME OF REGEN legend is on.
2. Press the
SET
button and the minute number on
the display starts flashing. If you want to change
this number, press the up arrow [↑] button to
increase the number or the down arrow [↓] button
to decrease the number. To skip the number
without changing, press the left arrow [←] button.
3. When the number is correct, press the left arrow
[←] button. The first number stops flashing and the
next number starts flashing. You can only change
the flashing number.
4. Continue changing numbers until you reach the
desired setting.
5. Press the
SET
button. The number stops flashing
and the control accepts the new setting. After
approximately 30 seconds, the control starts
alternating the display between TIME OF DAY and
CAPACITY.
Note:
If a beep sounds, the new setting is not
accepted.
Hardness Setting
The Hardness Setting refers to the amount of hardness
minerals in your water before it is conditioned. The
control uses this setting to calculate how many gallons
of water can be conditioned before a regeneration is
necessary.
Your water treatment dealer tested the water at the time
of installation and entered a Hardness Setting in the
control. We recommend that you consult your dealer or
have your water retested before changing this setting.
You can see the Hardness Setting the dealer entered by
pressing the down arrow [↓] button until the green light
next to the HARDNESS legend is on. The number on
the display is the measure of water hardness in grains
per gallon (milligrams per liter for metric).
Complete the following steps to change the Hardness
Setting:
1. Press the down arrow [↓] button until the green light
next to the HARDNESS legend is on. The setting
range is 3 to 250 grains/gallon (30 to
2500 milligrams/liter for metric).
2. Press the
SET
button and the first number starts
flashing. If you want to change this number, press
the up arrow [↑] button to increase the number or
the down arrow [↓] button to decrease the number.
To skip the number without changing, press the left
arrow [←] button.
3. When the number is correct, press the left arrow
[←] button. The first number stops flashing and the
next number starts flashing. You can only change
the flashing number.
4. Continue changing numbers until you reach the
desired setting.
5. Press the
SET
button. The number stops flashing
and the control accepts the new setting. After
approximately 30 seconds, the control starts
alternating the display between TIME OF DAY and
CAPACITY.
Note:
If a beep sounds, the new setting is not
accepted.
Reminder:
Whenever the HARDNESS or CAPACITY
setting is changed, you should regenerate the
conditioner by pressing the REGEN button.