Questions and Answers

  • A
    Andrew DawsonSep 3, 2025
    How to troubleshoot ERR 2 on Autotrol Logix 760?
    • L
      Lori MeltonSep 3, 2025
      If the Autotrol Control Unit displays ERR 2, the controller power doesn't match 50 or 60 Hz. Disconnect and reconnect the power. If the problem persists, obtain the appropriate controller or AC adapter for either 50 or 60 Hz power.
  • W
    wboyerSep 18, 2025
    Why is my Autotrol Control Unit leaking hard water after regeneration?
    • C
      Charles FuentesSep 18, 2025
      If you're experiencing hard water leakage after regeneration with your Autotrol Control Unit, it could be due to several reasons. First, the regeneration might be improper; repeat the regeneration after ensuring the correct regenerant dosage was set. Second, there might be leaking of the external bypass valve, so replace the bypass valve. Third, the O-ring around the riser pipe might be damaged, so replace the O-ring. Finally, the capacity might be incorrect; verify the appropriate regenerant amount and system capacity.
  • C
    Christopher GonzalesSep 16, 2025
    Why does Autotrol Logix 760 backwash at an excessively high rate?
    • W
      Whitney BeckerSep 16, 2025
      If the Autotrol Control Unit backwashes or purges at an excessively low or high rate, it could be due to using an incorrect drain controller, so replace it with the correct size controller. Another cause may be foreign matter affecting valve operation, so remove the drain controller and clean the ball and seat.
  • A
    Amanda MathisSep 15, 2025
    Why is there no conditioned water after regeneration in my Autotrol Control Unit?
    • E
      Ebony BlackSep 15, 2025
      If there is no conditioned water after regeneration with your Autotrol Control Unit, it could be due to a few reasons. First, check if there is no regenerant in the regenerant tank and add regenerant to the regenerant tank. Second, the injector might be plugged, so clean the injector and screen. Third, the air check valve might be closing prematurely, so put the control momentarily into brine/slow rinse, C2. Replace or repair air check if needed.
  • J
    Justin JacksonSep 13, 2025
    What to do if Autotrol Logix 760 has flowing water at drain after regeneration?
    • D
      Dustin HernandezSep 13, 2025
      If you have flowing or dripping water at the drain or brine line after regeneration with your Autotrol Control Unit, it may be because the valve stem return spring is weak and needs replacement. Another cause may be that debris is preventing the valve disc from closing, so remove the debris.
  • J
    Joshua LeachSep 12, 2025
    Why won't my Autotrol Logix 760 valve draw brine?
    • M
      Michael ClarkSep 12, 2025
      If the Autotrol Control Unit valve won't draw brine, it could be due to low water pressure, so set the pump to maintain 20 psi at the softener. It could also be due to a restricted drain line, so change the drain to remove the restriction. Another reason may be that the injector is plugged, so clean the injector and screen. Finally, the air check valve may be closing prematurely on the 255 valve or brine pickup tube. Put the control momentarily into brine/slow rinse, C2. Replace or repair air check if needed.
  • M
    Meghan DanielsSep 10, 2025
    Why is my Autotrol Control Unit drawing regenerant intermittently?
    • E
      Elizabeth OrrSep 10, 2025
      If you're experiencing intermittent or irregular regenerant draw with your Autotrol Control Unit, it could be due to low water pressure. Set the pump to maintain 20 psi at the conditioner. Another possible cause is a defective injector, which would require replacement.
  • B
    Bruce Holmes MDSep 8, 2025
    Why is my Autotrol Logix 760 Control Unit using more or less salt than the regenerant setting?
    • M
      moralestimothySep 8, 2025
      If the Autotrol Control Unit is using more or less salt than the regenerant setting, there might be foreign matter in the valve causing incorrect flow rates. Remove the brine control and flush out any foreign matter. Advance the control to brine/slow rinse, C2, to clean the valve, then position the control to “fast rinse, C7” to remove regenerant from the tank.
  • C
    Carol BakerSep 7, 2025
    What causes brine tank overflow in Autotrol Control Unit?
    • J
      Jason CohenSep 7, 2025
      If you experience a brine tank overflow with the Autotrol Control Unit, it could be due to: 1. Uncontrolled brine refill flow rate. Remove brine control to clean ball and seat. 2. Air leak in brine line to air check. Check all connections in brine line for leaks. Refer to instructions. 3. Drain control clogged with resin or other debris. Clean drain control.
  • H
    hperryAug 21, 2025
    What to do if Autotrol Control Unit displays ERR 3?
    • A
      alanbeardAug 21, 2025
      If the Autotrol Control Unit displays ERR 3, it means the controller can't determine the camshaft's position and the camshaft should be rotating to find Home position. Wait two minutes for the controller to return to the Home position; an hourglass should flash on the display, indicating the motor is running. If the camshaft isn't turning, check the motor connection, wire harness connections, optical sensor, and motor gear engagement. If the camshaft turns for more than five minutes, verify the optical sensor and camshaft connections, and check for obstructions in the cam slots. If problems persist, replace the wire harness, motor, optical sensor, and controller in that order.

Summary

LOGIX SERIES INSTALLER QUICK-START SHEET

Logix Series Controllers

Overview of Logix Series controllers and their functions.

Initial Power-up

Procedure for initial controller power-up and camshaft positioning.

Initial Start-up Step-by-step Instructions

Detailed steps for configuring system size, time, day, and regeneration settings.

Amount of Regenerant used per Regeneration

Guidance on setting the correct amount of salt for regeneration.

Enter Hardness (760 Demand Control Only)

Instructions for inputting water hardness for 760 Demand controls.

Resetting the Control

To reset the control

Procedure to reset the controller to its unprogrammed state.

WARNING: Resetting the control

Crucial warning about data loss when resetting the control.

EQUIPMENT INSTALLATION

General Warnings And Safety Information

Essential electrical and mechanical safety guidelines for installation.

System Regeneration Cycles (7-Cycle Operation)

Detailed explanation of the seven regeneration cycles.

Valve Features

Identification and description of 255 and Performa valve components.

Water Line Connection

Instructions and diagrams for connecting the water lines and bypass systems.

DETERMINING IF YOU HAVE A 740 OR 760 CONTROL

GENERAL 700 SERIES INSTRUCTIONS

DISPLAY ICONS 700 CONTROLLER

Regeneration Modes

Initial Start-up Step-By-Step Instructions

Step 1: Program System Size

Procedure to input the system's media volume or select filter mode.

Step 4: Set Regen Time

Procedure for setting the desired time for regeneration cycles.

Step 5: Set Days to Regenerate (740 Time-Clock Control Only)

Configuring regeneration frequency for 740 time-clock controls.

Step 5 a: Set Calendar Override (760 Demand Control Only)

Setting calendar override days for 760 demand controls.

Step 6: Amount of Regenerant used per Regeneration

Setting the salt amount for regeneration.

PLACING CONDITIONER INTO OPERATION (turning on the water)

Conditioner and FA Filter Start-Up

Steps to place the conditioner into operation after initial setup.

PROGRAMMING THE 700 FOR 5-CYCLE FILTER APPLICATIONS

VALVE SERVICE

Camshaft

Details on the camshaft's function and removal/installation.

PARTS AND ACCESSORIES

TROUBLESHOOTING

700 Series Controller Troubleshooting

Table of common problems, causes, and solutions for 700 series controllers.