EasyManuals Logo
Home>AUX>Inverter>AMWM-H18/4R3F

AUX AMWM-H18/4R3F User Manual

AUX AMWM-H18/4R3F
234 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
AUX DC Inverter Free Match 50HZ R32
64
Gas Side
mm(inc
h)
3×9.52(3/8) 9.52(3/8)
Max. length for all
rooms (m)
m 60 60
Max. length for
one IU (m)
m 30 30
Max. height
difference
between IU and
OU (m)
m 15 15
Max. height
difference
between IUs (m)
m 10 10
Ambient Temp (Cooling/Heating)
-15~52
/-15~24
-15~52
/-15~24
Stuffing
Quantity
20/40/40H unit 96/198/198 96/198/198
5.3 36K, 42K
DC INVERTER
Model
AM4-H36/4DR3
AM5-H42/4DR3
System Format
1 drive 4
1 drive 5
Capacity
Cooling
Btu/h
35826(8530~37532)
40944(9451~43332)
kW
10.50(2.5~11.0)
12(2.77~12.7)
Heating
Btu/h
37532(9110~38214)
44356(10100~44800)
kW
11.00(2.67~11.2)
13(2.96~13.1)
Electric Data
Power Supply
V~,Hz,Ph
220~240,50,1
220~240,50,1
Cooling Power
Input
W 3950(680~4930) 4450(750~5450)
Heating Power
Input
W 3150(530~3850) 3750(600~4350)
Rated Current
(cooling&heating)
A 17.5/13.96 19.72/16.62
Max current
A
23.5
24.5
Max power
KW
5.3
5.6

Table of Contents