AUX DC Inverter Free Match 50HZ R32
90
Note:
H = Height of Outdoor Unit Height of Indoor Unit
4.2 Correction capability
Cooling capacity = Rated cooling capacity xK1xK3
Heating capacity = Rated heating capacity xK2xK3
5. Equivalent Pipe length conversion
Equivalent pipe length means converting pipe elbow to straight pipe length after considerate
the pressure loss.
Bend and Oil Loop Conversion tablet
Type
Pipe Dia.(mm)
Bendm
Oil Loop(m)
6.35
0.10
0.7
9.52
0.18
1.3
12.70
0.20
1.5
15.88
0.25
2.0
19.05
0.35
2.4
22.02
0.40
3.0
Equivalent Pipe length LActual Pipe length L+ Bend Qty× Equivalent pipe bend length+ Oil
Loop Qty × Equivalent Oil Loop length
Sample:
ALCA-H42/5 Actual Pipe length is 25 meters, Gas pipe diameter is 15.88mm. If there’s 5