EasyManua.ls Logo

AUX AMWM-H18/4R3F - Part7 Capacity Amendment; 2. Capacity amendment of different ambient temperature

AUX AMWM-H18/4R3F
234 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AUX DC Inverter Free Match 50HZ R32
86
Part7 Capacity Amendment
1. Operation range
Cooling capacity
(KBtu/h)
12K 18K 24K 30K 36K 42K
Power supply
220-240V~/50Hz
Voltage
187~242V
Ambient
temperature
Cooling
-15~52
Heating
-15~24
2. Capacity amendment of different ambient temperature
2.1 Amendment coefficient of Cooling capacity under different indoor/outdoor DB/WB
temperature K1
IDU temp.
Outdoor air inlet DB temperature
DB
WB
-15
-10
0
10
16
25
30
35
40
43
48
52
23
16
1.26
1.19
1.12
1.08
1.05
1
0.95
0.90
0.87
0.85
0.82
0.77
25
18
1.28
1.26
1.19
1.12
1.08
1.05
1
0.95
0.90
0.87
0.85
0.82
27
19
1.30
1.28
1.26
1.19
1.12
1.08
1.05
1
0.95
0.90
0.87
0.85
28
20
1.33
1.30
1.28
1.26
1.19
1.12
1.08
1.05
1
0.95
0.90
0.87
30
22
1.5
1.33
1.30
1.28
1.26
1.19
1.12
1.08
1.05
1
0.95
0.90
32
24
1.7
1.5
1.33
1.30
1.28
1.26
1.19
1.12
1.08
1.05
1
0.95
Actual cooling capacity calculation:
Actual cooling capacity=amendment coefficient of cooling capacity × nominal cooling
capacity
——Rated cooling capacity could be found fromPart 4 Specification