AUX DC Inverter Free Match 50HZ R32
87
——Amendment coefficient of cooling capacity could be found from table above.
2.2 Amendment coefficient of heating capacity under different indoor/outdoor DB/WB
temperature K2
IDU temp.
Outdoor air inlet DB temperature
DB
-15
-10
-5
0
7
10
15
20
24
16
0.93
0.97
1
1.06
1.08
1.1
1.14
1.2
1.25
18
0.87
0.93
0.97
1
1.06
1.08
1.1
1.14
1.2
20
0.8
0.87
0.93
0.97
1
1.06
1.08
1.1
1.14
22
0.71
0.8
0.87
0.93
0.97
1
1.06
1.08
1.1
24
0.62
0.71
0.8
0.87
0.93
0.97
1
1.06
1.08
Actual heating capacity calculation:
Actual heating capacity=amendment coefficient of heating capacity × nominal heating
capacity
——Rated heating capacity could be found fromPart 4 Specification
——amendment coefficient of heating capacity could be found from table above.